COMPANY HEADER
Request Information
Connector-plugs use an assortment of connecting technologies such as screw connections, spring clamp connections and a push-in design structure. The plug components are available in a variety of wire entry angles and mounting structures.
Unit of Measure

Specifications

Connection Method

N/A Screw Connection

Pitch Diameter

N/A 0.2 in5.08 mm

Current Rating

N/A 12 A

Rated Voltage

N/A 300 V

Solid Wire Gauge

N/A 24 - 12 AWG

Striped Wire Gauge

N/A 24 - 12 AWG

Level

N/A Single Level

Type of Locking

N/A With Screw Flange

Conductor Material

N/A Copper Alloy

Conductor Plating

N/A Tin Plated

Insulation Material

N/A Polyamide (PA)

Flammability Standard

N/A Underwriters Laboratories (UL94 V0)

Wire Strip Length

N/A 7~8 mm

Screw Thread

N/A M2.5

Rated Voltage According to Underwriters Laboratories (UL)

N/A 300 V

Rated Voltage According to International Electrotechnical Commission (IEC)

N/A 250 V

Rated Current According to Underwriters Laboratories (UL)

N/A 12 A

Rated Current According to International Electrotechnical Commission (IEC)

N/A 12 A

Solid Wire Gauge According to Underwriters Laboratories (UL)

N/A 24~12 AWG/mm²

Solid Wire Gauge According to International Electrotechnical Commission (IEC)

N/A 0.5~2.5 AWG/mm²

Flexible Wire Gauge According to Underwriters Laboratories (UL)

N/A 24~12 AWG/mm²

Flexible Wire Gauge According to International Electrotechnical Commission (IEC)

N/A 0.5~2.5 AWG/mm²

Rated Impulse Voltage According to International Electrotechnical Commission (IEC)

N/A 2.5 kV

Number of Position

N/A 02~12

Remarks

N/A Screw Flange

Rated Torque

N/A 0.6 N·m

Type

N/A Printed Circuit Boards (PCB)

Approval

N/A Underwriters Laboratories (cRUus)

Applications

N/A Electronic Housing

Accessories

Accessories

N/A EHDK1