Items |
/Asset/a4495.jpg 0191-01XX 0191-01XX 0.138 Inch (in) Pitch Diameter Printed Circuit Board (PCB) Connector-Plug |
/Asset/a4497.jpg 0191-01XXC 0191-01XXC 0.138 Inch (in) Pitch Diameter Printed Circuit Board (PCB) Connector-Plug |
/Asset/a4499.jpg 0184-11XX 0184-11XX 0.138 Inch (in) Pitch Diameter Printed Circuit Board (PCB) Connector-Plug |
/Asset/a4501.jpg 0184-12XX 0184-12XX 0.138 Inch (in) Pitch Diameter Printed Circuit Board (PCB) Connector-Plug |
/Asset/a4503.jpg 0184-13XX 0184-13XX 0.138 Inch (in) Pitch Diameter Printed Circuit Board (PCB) Connector-Plug |
|||||
Description | N/A Connector-plugs use an assortment of connecting technologies such as screw connections, spring clamp connections and a push-in design structure. The plug components are available in a variety of wire entry angles and mounting structures. | |||||||||
Model | N/A | |||||||||
Connection Method | N/A Push-In Design (PID) | |||||||||
Pitch Diameter | N/A 0.138 in3.50 mm | |||||||||
Current Rating | N/A 2 A | N/A 2 A | N/A 7 A | N/A 7 A | N/A 7 A | |||||
Rated Voltage | N/A 150 V | |||||||||
Solid Wire Gauge | N/A 28 - 16 AWG | N/A 28 - 16 AWG | N/A 24 - 16 AWG | N/A 24 - 16 AWG | N/A 24 - 16 AWG | |||||
Striped Wire Gauge | N/A 28 - 16 AWG | N/A 28 - 16 AWG | N/A 24 - 16 AWG | N/A 24 - 16 AWG | N/A 24 - 16 AWG | |||||
Level | N/A Single Level | |||||||||
Type of Locking | N/A Without | N/A Without | N/A Without | N/A With Lock Flange | N/A Without | |||||
Conductor Material | N/A Stainless Steel | N/A Stainless Steel | N/A Copper Alloy | N/A Copper Alloy | N/A Copper Alloy | |||||
Conductor Plating | N/A Tin Plated | |||||||||
Insulation Material | N/A Polyamide (PA) | |||||||||
Flammability Standard | N/A Underwriters Laboratories (UL94 V0) | |||||||||
Wire Entry/Plug Direction | N/A | |||||||||
Hook Position | N/A | |||||||||
Wire Strip Length | N/A 8 mm | N/A 8 mm | N/A 8~9 mm | N/A 8~9 mm | N/A 8~9 mm | |||||
Screw Thread | N/A | |||||||||
Product Series (Testing Hole Dimensions) | N/A | |||||||||
Hole Diameter | N/A | |||||||||
Rated Voltage According to Underwriters Laboratories (UL) | N/A 150 V | |||||||||
Rated Voltage According to International Electrotechnical Commission (IEC) | N/A 160 V | N/A 160 V | N/A 320 V | N/A 320 V | N/A 320 V | |||||
Rated Current According to Underwriters Laboratories (UL) | N/A 2 A | N/A 2 A | N/A 6 A | N/A 6 A | N/A 6 A | |||||
Rated Current According to International Electrotechnical Commission (IEC) | N/A 4 A | N/A 4 A | N/A 5 A | N/A 5 A | N/A 5 A | |||||
Solid Wire Gauge According to Underwriters Laboratories (UL) | N/A 28~16 AWG/mm² | N/A 28~16 AWG/mm² | N/A 24~16 AWG/mm² | N/A 24~16 AWG/mm² | N/A 24~16 AWG/mm² | |||||
Solid Wire Gauge According to International Electrotechnical Commission (IEC) | N/A 0.5~1.5 AWG/mm² | N/A 0.5~1.5 AWG/mm² | N/A 0.2~1.5 AWG/mm² | N/A 0.2~1.5 AWG/mm² | N/A 0.2~1.5 AWG/mm² | |||||
Flexible Wire Gauge According to Underwriters Laboratories (UL) | N/A 28~16 AWG/mm² | N/A 28~16 AWG/mm² | N/A 24~16 AWG/mm² | N/A 24~16 AWG/mm² | N/A 24~16 AWG/mm² | |||||
Flexible Wire Gauge According to International Electrotechnical Commission (IEC) | N/A 0.5~1.5 AWG/mm² | N/A 0.5~1.5 AWG/mm² | N/A 0.2~1.5 AWG/mm² | N/A 0.2~1.5 AWG/mm² | N/A 0.2~1.5 AWG/mm² | |||||
Rated Impulse Voltage According to International Electrotechnical Commission (IEC) | N/A 3 kV | N/A 3 kV | N/A 2.5 kV | N/A 2.5 kV | N/A 2.5 kV | |||||
Number of Position | N/A 02~20 | N/A 02~20 | N/A 02~24 | N/A 02~24 | N/A 02~24 | |||||
Socket | N/A | |||||||||
Pin Strip | N/A 0191-11XXTH | N/A 0191-11XXTH | N/A | N/A | N/A | |||||
Remarks | N/A | N/A With Cover | N/A | N/A | N/A | |||||
Rated Impulse Voltage According to Underwriters Laboratories (UL) | N/A | |||||||||
Printed Circuit Board (PCB) Thickness | N/A | |||||||||
Rated Torque | N/A | |||||||||
Type | N/A Printed Circuit Boards (PCB) | |||||||||
Approval | N/A Underwriters Laboratories (cRUus) | N/A Underwriters Laboratories (cRUus) | N/A | N/A | N/A | |||||
Applications | N/A Electronic Housing | |||||||||
Features | N/A | |||||||||
Note | N/A | |||||||||
|